  "status": "PRELIMINARY_DESIGN_NOT_VALIDATED",
  "initial_load_kg": 10000,
  "initial_whole_wb": 0.5,
  "final_whole_wb_scenario": 0.08,
  "water_removed_kg": 4565.217391304348,
  "bulk_density_assumed_kg_m3": 350,
  "net_product_volume_m3": 28.571428571428573,
  "cone_volume_m3": 4.110250388446646,
  "cylinder_gross_m3": 39.58406743523139,
  "fill_top_above_ground_m": 2.865137204816267,
  "maximum_bed_depth_m": 1.2651372048162668,
  "fan_duty_per_train": {
    "actual_inlet_m3_h": 30000,
    "inlet_C": 25,
    "static_pressure_Pa": 10000,
    "efficiency_assumed": 0.7,
    "calculated_shaft_kW": 119.04761904761907,
    "motor_envelope_kW": 160,
    "manufacturer_curve_selected": false
  },
  "air": {
    "ambient_RH": 0.6,
    "ambient_C": 25,
    "heated_C": 80,
    "cold_total_actual_m3_h": 120000,
    "hot_total_actual_m3_h": 142136.50846889146,
    "ideal_exhaust_C": 35.82636503007875,
    "ideal_exhaust_RH": 0.8,
    "ideal_exhaust_total_actual_m3_h": 127975.1666152272,
    "duct_clear_area_per_train_m2": 0.54,
    "duct_hot_velocity_m_s": 18.278871973880072,
    "exhaust_total_area_m2": 2.0106192982974678,
    "exhaust_velocity_m_s": 17.68045170123464,
    "superficial_bed_velocity_m_s": 1.3964029578177235,
    "heater_sensible_only_kW": 2189.757023103598
  },
  "Ergun_sensitivity": [
    {
      "porosity": 0.35,
      "maximum_bed_depth_m": 1.2651372048162668,
      "Ergun_bed_only_Pa": 4274.025235371013
    },
    {
      "porosity": 0.4,
      "maximum_bed_depth_m": 1.2651372048162668,
      "Ergun_bed_only_Pa": 2632.8223262907645
    },
    {
      "porosity": 0.45,
      "maximum_bed_depth_m": 1.2651372048162668,
      "Ergun_bed_only_Pa": 1688.4621744464796
    }
  ],
  "heater_installed_kW": 2400,
  "installed_electric_kW": 3067.5,
  "battery_nominal_MWh_proposed": 14,
  "battery_nominal_MWh_min_3h_full_load": 12.237367021276595,
  "PCS_MW_proposed": 3.5,
  "PV_MWp_selected": false,
  "target_scenarios": [
    {
      "hours_target": 2,
      "water_kg_h": 2282.608695652174,
      "hot_inlet_m3_h": 126211.91594862595,
      "ideal_heater_kW": 1944.4225296159768
    },
    {
      "hours_target": 3,
      "water_kg_h": 1521.7391304347827,
      "hot_inlet_m3_h": 84141.27729908396,
      "ideal_heater_kW": 1296.2816864106512
    }
  ],
  "real_drying_test": false,
  "CFD": false,
  "DEM": false,
  "strength_checked": false,
  "assertions": [
    "mass closure",
    "fan power arithmetic",
    "3h full-load battery arithmetic"
  ]
}